High voltage DC contactor manufacturer - Changzhou Apollo Automobile Technology Co. Ltd
High voltage DC contactor apl300a-hfd can cut off 2000a current at 450VDC;Small size and light weight.Auxiliary contact 250ac/0.5A;The switch part and the driving part are inflatable and airtight, so that they can cut off the high capacity load;Fully sealed structure, high safety: used in explosive or harmful environment, its coil and contact do not oxidize, even if it does not work for a long time;Built in energy-saving coil, low holding power, back EMF close to 0V
Model: APL300A-HFD
application scope:
uses include electric vehicle, fast charging pile, battery switching and backup, high voltage DC voltage switch control, circuit protection and safety control, etc
product features:
● the maximum current of 2000a can be cut off at 450VDC;Small size and light weight.Auxiliary contact 250AC/0.5A
● the switch part and drive part are inflatable and sealed, which can cut off high capacity load
● fully sealed structure, high safety: used in explosive or harmful environment, its coil and contact do not oxidize, even if it does not work for a long time
● built in energy saving coil.Low holding power, back EMF close to 0V
● CE/ROHS certification, the design conforms to UL/CSA Standard UL 508
model explanation:
shape and installation dimension:
coil working voltage (suitable for the whole temperature range):
Number | Working voltage | 9-36VDC |
1 | Maximum voltage | 36VDC |
2 | Maximum pull-in voltage | 9VDC |
3 | Minimum maintenance voltage | 7.5VDC |
4 | Minimum release voltage | 6VDC |
5 | Maximum surge current | 3.8A |
6 | Mean holding current | 0.13A(12V)0.07A(24V) |
7 | Maximum surge time | 130ms |
technical parameters:
category | parameter | unit | value |
Main contact | Main contact, contact form | / | A set of bridge type normally open (double acting contact) |
Operating voltage range | VDC | 12—900 | |
Maximum short circuit current | A | 2000A | |
Withstand voltage | VAC | ≥4000(1mA) | |
Insulation resistance under DC 500V | MΩ | ≥100 | |
Standard contact resistance | MΩ | ≤3 | |
Auxiliary contact | Auxiliary contact, contact form | / | A set of normally open (SPST-NO) |
Maximum current of auxiliary contacts | A | 30VDC 2A: 125VAC 3A | |
Minimum current value of laying contact | mA | 8v 100mA | |
Maximum contact resistance of auxiliary contacts | Ω | 30VDC 0.417Ω;125VAC 0.150Ω | |
lifetime | Load life (30A/ 450V) | times | ≥2000 |
Mechanical life | times | 2,000.00 | |
And the release of | And the time | ms | ≤25 |
The maximum value of contact bounce (after pulling only) | ms | ≤7 | |
Release time | ms | ≤12 | |
environment | Shock, 11ms,1/2 sine wave, peak, suction | G | ≤50 |
Peak sinusoidal vibration | G | ≤20 | |
Working temperature | ℃ | —40—+85 | |
Operating humidity range | RH% | 5—85 | |
standard weight | (Kg) | ≤0.45 |
product electrical life curveContinuous power on capability curve:
precautions for application: A1 + terminal is input (in);A2 terminal is output (out);See the real product for details
the life end of the contactor, that is, the insulation strength between the leading out load terminals of the insulation meter is lower than 50 megohm when the DC voltage is 500V
(1) do not touch the load terminal when the relay is powered on to avoid the risk of electric shock
(2) the load voltage should be cut off when the control circuit and non-metallic materials are subjected to withstand voltage test
(3) avoid installing the product in the place with strong magnetic field (transformer or magnet), or close to the object with thermal radiation
(4) do not touch the main lead-out terminal with foreign matters and oil stains, and the external lead-in wire terminal and the main lead-out terminal are in reliable contact, otherwise the terminal will be heated severely and the connecting cable will be melted
(5) in the action voltage test, do not make the voltage rise slowly, please drive the coil by step power supply
(6) the bolt locking torque of each installation part shall be controlled within the specified range.The locking torque of the nut at the load installation position is 7N.M;In principle, please do not use it when the stud torque of relay installation part is 8-9N.M
(7) it falls outside the relay and is impacted