APL30A-12HAD

Description:


    The charging capacity is more than 30A, and 150A current can be cut off under 320VDC;In volume, light weight;The switch part and the driving part are inflatable and airtight, so that they can cut off the high capacity load;Fully sealed structure, high safety;When used in explosive or harmful environment, the coil and contact do not oxidize, even if they do not work for a long time;Comply with EU ROHS Directive (2011/65/EU) and ul508 standard

Model: APL30A-12HAD

Application scope:

Applications include electric vehicle auxiliary electrical switching control, pre charging control, battery switching and electric motorcycle high voltage DC voltage switch control, circuit protection and safety control

Product features:

The electrifying capacity is more than 30A, and 150A current can be cut off under 320VDC;In volume, light weight

The switch part and the drive part are inflatable and sealed, so that they can cut off the high capacity load

Fully sealed structure, high safety;Used in explosive or harmful environment, its coil and contact do not oxidize, even if it does not work for a long time

Comply with EU ROHS Directive (2011/65/EU) and ul508 standard

1619317903621938.jpg

Number Working voltage 12VDC 24VDC 48VDC
1 Maximum voltage 16VDC 28VDC 52VDC
2 Maximum absorption voltage 9VDC 18VDC 36VDC
3 Minimum release voltage 1.2VDC 2.4VDC 4.8VDC
4 Coil current 461mA 250mA 122mA
5 coil power(20℃) 5.5W 6.0W 6.0W
6 Coil resistance(20℃)±5%Ω 26 96 392


1620612482738138.jpg


category parameter unit value
Main contact Main contact, contact form / A set of bridge type normally open
(double acting contact)
Operating voltage range VDC 12—750
Maximum short circuit current A 1250A
Withstand voltage VAC ≥2500(leakage1mA)
Insulation resistance under DC 500V ≥100
Standard contact resistance ≤5
Auxiliary contact Auxiliary contact, contact form /
Maximum current of auxiliary contacts A
Minimum current value of laying contact mA
Maximum contact resistance of auxiliary contacts Ω
lifetime Load life (30A/ 450V) times ≥8000
Mechanical life times 2,000.00
And the release of And the time ms ≤15
The maximum value of contact bounce
(after pulling only)
ms ≤5
Release time ms ≤12
environment Shock, 11ms,1/2 sine wave, peak, suction G ≤50
Peak sinusoidal vibration G ≤20
Working temperature —40—+85
Operating humidity range RH% 5—85
standard weight (Kg) ≤0.19





1620612525978270.jpg


You may need

Add or consult other products

APL300A-HFD
    

APL250A-HFD
    

APL200A-HFD
    

APL150A-24HFD
    

APL150A-12HFD
    

APL100A-24HFD
    

APL100A-12HFD
    

APL300A-HAD
    

Relevant information

Contactor/relay related news, technology and topics of discussion

Cause of overcu

2021-08-23

The overview an

2021-08-14

Direct point ar

2021-08-12

How to select d

2021-07-22

Use ceramic sea

2021-07-12

Dc contactor ty

2021-07-09

Dc contactor co

2021-07-06

Dc contactor ar

2021-07-03