High voltage DC contactor manufacturer - Changzhou Apollo Automobile Technology Co. Ltd

APL100A-12HFD

Description:


    High voltage DC relay apl100a-12hfd, the maximum installation processing cabinet is 2.3n. M, the contact installation torque is 3.4 to 4.5n. M, and the maximum depth of internal thread is 7.2mm

Model: apl100a-12hfd

application scope:

high voltage main circuit, pre charging circuit, slow charging circuit, fast charging circuit, high voltage auxiliary system, etc. of new energy vehicles;High voltage main circuit system of charging pile;Wind power, photovoltaic and other power control systems

product features:


● fully sealed structure, high safety

● coil voltage: 12, 24 and 48V

● small volume, high switching power

● epoxy sealing technology is used to fully seal the product, protecting the coil and contact system from oxidation for a long time

Executive standard: GB/T14048.4-2010

model explanation:

1620617667485612.jpg

shape and installation size:

1620617702976821.jpg

coil working voltage (suitable for the whole temperature range):

NumberWorking voltage12VDC24VDC48VDC
1Maximum voltage16VDC28VDC52VDC
2Maximum absorption voltage9VDC18VDC36VDC
3Minimum release voltage1.2VDC2.4VDC4.8VDC
4Coil current461mA250mA122mA
5coil power(20℃)5.5W6.0W6.0W
6Coil resistance(20℃)±5%Ω2696392

technical parameters:

categoryparameterunitvalue
Main contactMain contact, contact form/A set of bridge type normally open
(double acting contact)
Operating voltage rangeVDC12—900
Maximum short circuit currentA1250A(1/2次,60Hz)
Withstand voltageVAC≥2500(1mA)
Insulation resistance under DC 500V≥100
Standard contact resistance≤5
Auxiliary contactAuxiliary contact, contact form/A set of normally open (SPST-NO)
Maximum current of auxiliary contactsA30VDC 2A: 125VAC 3A
Minimum current value of laying contactmA8v 100mA
Maximum contact resistance of auxiliary contactsΩ30VDC 0.417Ω;125VAC 0.150Ω
lifetimeLoad life (30A/ 450V)times≥6000
Mechanical lifetimes2,000.00
And the release ofAnd the timems≤25
The maximum value of contact bounce
(after pulling only)
ms≤5
Release timems≤10
environmentShock, 11ms,1/2 sine wave, peak, suctionG≤50
Peak sinusoidal vibrationG≤20
Working temperature—40—+85
Operating humidity rangeRH%5—85
standard weight(Kg)≤0.19

product electrical life curveContinuous energizing capacity curve:

1620618195411965.jpg

precautions for application:

the life end of contactor, that is, the insulation strength between the leading load ends of the insulation meter is lower than 50 megohm when the DC is 500V

(1) do not touch the load terminal when the relay is energized,Beware of electric shock

(2) the load voltage should be cut off when the control circuit and non-metallic materials are subjected to withstand voltage test

(3) avoid installing the product in the place with strong magnetic field (transformer or magnet), or close to the object with thermal radiation

(4) do not touch the main lead-out terminal with foreign matters and oil stains, and the external lead-in wire terminal and the main lead-out terminal are in reliable contact, otherwise the terminal will be heated severely and the connecting cable will be melted

(5) in the action voltage test, do not make the voltage rise slowly, please drive the coil by step power supply

(6) the bolt locking torque of each installation part shall be controlled within the specified range.The locking torque of the nut at the load installation position is 7n. M;In principle, please do not use it when the stud torque of relay installation part is 8-9n. M

(7) it falls outside the relay and is impacted


You may need

Add or consult other products

APL300A-HFD
    

APL250A-HFD
    

APL200A-HFD
    

APL150A-24HFD
    

APL150A-12HFD
    

APL100A-24HFD
    

APL100A-12HFD
    

APL300A-HAD
    

Relevant information

Contactor/relay related news, technology and topics of discussion

Cause of overcu

2021-08-23

The overview an

2021-08-14

Direct point ar

2021-08-12

How to select d

2021-07-22

Use ceramic sea

2021-07-12

Dc contactor ty

2021-07-09

Dc contactor co

2021-07-06

Dc contactor ar

2021-07-03